本文以 PowerPCB 提供的 Pwrdemoa.pcb為例進(jìn)行說(shuō)明。
1.打開(kāi) PCB 圖,? 選擇菜單 File-Report,文件類型選 PowerPCB V3.0 Format Netlist ,將文件另存為Pwrdemoa.ASC。?
2.啟動(dòng)程序 Omninet for Windows,輸入文件類型(Type)選 Pads-PowerPCB,Input File 1里用 Browse 指定網(wǎng)絡(luò)表文件的位置。
???? 輸出文件類型(Type)選 EDIF。Output File 1 指定輸出文件的文件名和路徑。
???? 然后點(diǎn)擊 Run(跑動(dòng)的小人)。
?
系統(tǒng)彈出一個(gè)輸出窗口
?
點(diǎn)擊 Accept Data。完成后點(diǎn)擊“確定”,再點(diǎn)擊“Done”關(guān)閉輸出窗口。退
出 Omninet for Windows。
?
3.修改 EDIF 網(wǎng)表文件,非常麻煩且容易出錯(cuò)的部分。下面是網(wǎng)絡(luò)表的一部分:?
?
? (edif? (rename? C_COLON_BSLTEMP_BSLPWRDEMOA_DOTEDF
"C:\TEMP\PWRDEMOA.EDF")
? (edifVersion 2 0 0)
?(edifLevel 0)
? (keywordMap (keywordLevel 0))
?(library MAIN_LIB
? (edifLevel 0)
? (technology
?? (numberDefinition
??????? (scale 1 (e 1 -6)(unit distance)))
? )
??? (cell &6167 (cellType generic)
?? (view NetlistView (viewType netlist)
??? (interface
??? )
?? )
? )
? (cell &6167 (cellType generic)
?? (view NetlistView (viewType netlist)
??? (interface
???? (port &1 )
???? (port &2 )
???? (port &3 )
???? (port &4 )
???? (port &5 )
???? (port &6 )
???? (port &7 )
???? (port &10 )
???? (port &13 )
???? (port &14 )
???? (port &15 )
???? (port &16 )
???? (port &17 )
???? (port &18 )
???? (port &19 )
???? (port &20 )
??? )
?? )
? )
? (cell &68HC68R2 (cellType generic)
?? (view NetlistView (viewType netlist)
??? (interface
???? (port &1 )
???? (port &2 )
???? (port &3 )
???? (port &4 )
???? (port &5 )
???? (port &6 )
???? (port &7 )
???? (port &8 )
??? )
?? )
? )
??? (cell &68HC68R2 (cellType generic)
?(view NetlistView (viewType netlist)
??? (interface
??? )
?? )
? )?
? (cell (rename NE555_MINUSSO "NE555-SO") (cellType generic)
?? (view NetlistView (viewType netlist)
??? (interface
??? )
?? )
? )
? (cell (rename R1_FSL4W "R1/4W") (cellType generic)
?? (view NetlistView (viewType netlist)
??? (interface
??? )
?? )
? )
? (cell (rename R1_FSL4W "R1/4W") (cellType generic)
?? (view NetlistView (viewType netlist)
??? (interface
???? (port &1 )
???? (port &2 )
??? )
?? )
? )
???? 檢查一下有(cell…..標(biāo)記的行,特別要注意紅色字體部分,其 Interface 部分為空,在這個(gè) cell 標(biāo)記的前面或后面又有一個(gè)cell 行,其 Interface部分包含有
(port &1)
(port & 2)
? .
? .
? .
等內(nèi)容。就是說(shuō)每種器件出現(xiàn)了兩個(gè) cell 定義。
???? 現(xiàn)在要做的就是將無(wú) port 內(nèi)容的 cell 標(biāo)記刪除(上述 EDIF 文件中紅色字體部分)。PCB板中有多少種 Part Type,就需要?jiǎng)h除多少Cell 標(biāo)記,還要注意不要把有 port 內(nèi)容的那些行刪掉了。多刪了或者少刪了都會(huì)造成網(wǎng)絡(luò)不完整,從而丟失信息。
???? 將修改后的 EDIF文件存盤。?
4.啟動(dòng) E-Studio 軟件,打開(kāi)第3 步保存的 EDIF文件。
?
5.右鍵點(diǎn)擊 PWRDEMOA.EDF文件,選擇 Generate Schamatics:
?
系統(tǒng)彈出窗口。
?
點(diǎn)擊確定。
??? 6.選擇菜單 File-Save As,輸出格式選 ORCAD 9.10。
?
點(diǎn)擊 Save 保存。彈出窗口中點(diǎn)擊“確定”結(jié)束。
???? 生成的原理圖已經(jīng)可以在 ORCAD 中打開(kāi)了。圖紙顯得特別長(zhǎng)。如果 PCB比較復(fù)雜,可能會(huì)出現(xiàn)原理圖太大,以致軟件都沒(méi)法處理的情況。下圖只是原理圖的一部分。
?
6.在 ORCAD 中打開(kāi)生成的原理圖,啟動(dòng) PCBNavigator,打開(kāi) ITC 連接PowerPCB。選擇菜單 PCB->Compare Netlist with PCB,生成的報(bào)告文件如下:
?
*PADS-ECO-V3.0-MILS*
*REMARK*?? old file: D:\padspwr\Files\ecogtmp0.asc
*REMARK*?? new file: C:\TEMP\pwrdemoa.asc
*REMARK*?? created by ECOGEN (Version 6.0g) on 2004-10-8 21:39:40
?
PART DIFFERENCES
----------------
OLD DESIGN??????????????????????????????????????????????????????????? NEW DESIGN
Ref-des? Part-type:Decal???????????????????????????????? Ref-des? Part-type:Decal
P2???? CON\60P\100\ED????????????????????????????????????????????? P2??? ED
J1???? CON\RIB14HL????????????????????????????????????????????????? J1??? RIB14HL
R1??? R1/4W?????????????????????????????????????????????????????????? R1???? 4W
R10?? R1/4W?????????????????????????????????????? R10?? 4W
R11??? R1/4W????????????????????????????????????????????????????????? R11???? 4W
R12?? R1/4W?????????????????????????????????????? R12?? 4W
R14?? R1/4W?????????????????????????????????????? R14?? 4W
R16?? R1/4W?????????????????????????????????????? R16?? 4W
R2??? R1/4W?????????????????????????????????????????????????????????? R2???? 4W
R5??? R1/4W?????????????????????????????????????????????????????????? R5???? 4W
R6??? R1/4W?????????????????????????????????????????????????????????? R6???? 4W
R7??? R1/4W?????????????????????????????????????????????????????????? R7???? 4W
NET DIFFERENCES
----------------
OLD DESIGN??????????????????????????????????????? NEW DESIGN
?
SWAPPED GATE DIFFERENCES
------------------------
OLD DESIGN??????????????????????????????????????? NEW DESIGN
?
SWAPPED PIN DIFFERENCES
------------------------
OLD DESIGN??????????????????????????????????????? NEW DESIGN
?
?
UNMATCHED NET PINS IN OLD DESIGN
--------------------------------
?
UNMATCHED NET PINS IN NEW DESIGN
--------------------------------
?
ATTRIBUTE DIFFERENCES
---------------------
Attribute Level? [ OLD DESIGN Parent -> NEW DESIGN Parent ]
?
????????? Attribute Name?????????? Old Value??????????????? New Value
?
可以看出,除了器件類型中包含有斜杠(不論正反)被改名外,網(wǎng)絡(luò)表沒(méi)有任何差異。
???? 如果要求完美,可以對(duì)照 PCB 圖將原理圖中的器件型號(hào)再改回去,這樣就能實(shí)現(xiàn)原理圖與 PCB 的完全對(duì)應(yīng)。
???? 如果沒(méi)有 PCBNavigator,可以用 ORCAD 生成 PADSPCB格式的網(wǎng)絡(luò)表,在PowerPCB 的 Tools 菜單的 Compare/ECO Tools 中進(jìn)行比較,第一個(gè)文件選當(dāng)前設(shè)計(jì)文件,第二個(gè)文件選 ORCAD 生成的 ASCII 網(wǎng)表文件,其比較結(jié)果是一樣的。
???? 到此,PowerPCB 轉(zhuǎn) ORCAD原理圖結(jié)束。?
???? 需要說(shuō)明的是,這樣的轉(zhuǎn)換對(duì)于 PCB 上元件較少的情況可能好用,但如果PCB 上元件很多,則轉(zhuǎn)換出來(lái)的原理圖非常龐大,網(wǎng)絡(luò)連接極其復(fù)雜,它沒(méi)有層次、總線概念,也不會(huì)分成多張子圖,所有網(wǎng)絡(luò)是全部連接的,要能看懂可能還是比較困難。
另外,PCB 中沒(méi)有連接的管腳在轉(zhuǎn)換出來(lái)的原理圖上不再存在,可能會(huì)出現(xiàn)有些器件管腳數(shù)不對(duì)的情況。若要修改原理圖,必須修改生成的器件符號(hào)。
?????? 還有一點(diǎn)不完善的地方是器件的封裝信息沒(méi)有了,必須重新填寫。不過(guò)用ORCAD 做原理圖有個(gè)優(yōu)勢(shì),就是不寫封裝,生成網(wǎng)絡(luò)表時(shí)會(huì)以器件的 Value 作為封裝,不影響網(wǎng)絡(luò)表生成。
評(píng)論