資料介紹
Heart Rate and EKG Monitor using the MSP430FG439:This application report describes how to build a digital heart rate monitor using a MSP430FG439 microcontroller (MCU). The heart beat rate per minute is displayed on a LCD glass. In addition to this the application outputs digital data stream via RS232 serial port to allow EKG waveform display on a PC. PCB Gerber files, schematic, bill of materials and firmware are provided in a zip file associated with this application report.The entire application runs using a CR2032 3-Volt lithium battery.
An electrocardiogram (ECG) also called EKG is a graphic tracing of the voltage generated by the cardiac or heart muscle during a heartbeat. It provides very accurate evaluation of the performance of the heart.The heart generates an electrochemical impulse that spreads out in the heart in such a fashion as to cause the cells to contract and relax in a timely order and thus give the heart a pumping characteristic.This sequence is initiated by a group of nerve cells called the sinoatrial (SA) node resulting in a polarization and depolarization of the cells of the heart. Because this action is electrical in nature and because the body is conductive with its fluid content, this electrochemical action can be measured at the surface of the body.
An actual voltage potential of approximately 1mV develops between various body points. This can be measured by placing electrode contacts on the body. The four extremities and the chest wall have become standard sites for applying the electrodes. Standardizing electrocardiograms makes it possible to compare them as taken from person to person and from time to time from the same person. The normal electrocardiogram shows typical upward and downward deflections that reflect the alternate contraction of the atria (the two upper chambers) and of the ventricles (the two lower chambers) of the heart.A typical single cardiac cycle waveform of a normal heartbeat is shown in Figure 1-1. The voltages produced represent pressures exerted by the heart muscles in one pumping cycle. The first upward deflection, P, is due to atria contraction and is known as the atrial complex. The other deflections, Q, R, S, and T, are all due to the action of the ventricles and are known as the ventricular complexes. Any deviation from the norm in a particular electrocardiogram is indicative of a possible heart disorder.In this application report the EKG waveform is used by the MCU to measure the heart beat rate. Because heart beat calculation is the major focus the electrodes are simplified to two connections one to a right arm and the other to the left arm. This type of set up can be frequently seen in exercise machines such as
a treadmill.
An electrocardiogram (ECG) also called EKG is a graphic tracing of the voltage generated by the cardiac or heart muscle during a heartbeat. It provides very accurate evaluation of the performance of the heart.The heart generates an electrochemical impulse that spreads out in the heart in such a fashion as to cause the cells to contract and relax in a timely order and thus give the heart a pumping characteristic.This sequence is initiated by a group of nerve cells called the sinoatrial (SA) node resulting in a polarization and depolarization of the cells of the heart. Because this action is electrical in nature and because the body is conductive with its fluid content, this electrochemical action can be measured at the surface of the body.
An actual voltage potential of approximately 1mV develops between various body points. This can be measured by placing electrode contacts on the body. The four extremities and the chest wall have become standard sites for applying the electrodes. Standardizing electrocardiograms makes it possible to compare them as taken from person to person and from time to time from the same person. The normal electrocardiogram shows typical upward and downward deflections that reflect the alternate contraction of the atria (the two upper chambers) and of the ventricles (the two lower chambers) of the heart.A typical single cardiac cycle waveform of a normal heartbeat is shown in Figure 1-1. The voltages produced represent pressures exerted by the heart muscles in one pumping cycle. The first upward deflection, P, is due to atria contraction and is known as the atrial complex. The other deflections, Q, R, S, and T, are all due to the action of the ventricles and are known as the ventricular complexes. Any deviation from the norm in a particular electrocardiogram is indicative of a possible heart disorder.In this application report the EKG waveform is used by the MCU to measure the heart beat rate. Because heart beat calculation is the major focus the electrodes are simplified to two connections one to a right arm and the other to the left arm. This type of set up can be frequently seen in exercise machines such as
a treadmill.
下載該資料的人也在下載
下載該資料的人還在閱讀
更多 >
- SM2255EKG高功率因數LED線性恒流控制芯片中文手冊 0次下載
- process-monitor進程守護者
- WildFly Monitor監控數據發送工具
- 如何使用具有MSP430 USI端口的ADS8361的詳細資料概述 13次下載
- Predicting Op Amp Slew Rate Limi 0次下載
- HEART_RATE_PROFILE 0次下載
- Heart-RateFitness Monitors Go Wireless 33次下載
- AVR利用USI模塊作為I2C從機 82次下載
- Heart-Rate and EKG Monitor Usi
- Slew Rate of Op Amp Circuits
- Design of Crimp force Monitor
- Serial Monitor (串口監視、檢測、分析工具)v
- Implementing Double Data Rate
- DS2155 Monitor Mode Design
- USB Monitor Control Class Spec
- DDR和LPDDR內存技術的相同點和不同點比較 3369次閱讀
- 請問運算放大器Slew Rate指標在系統應用中有何意義呢? 808次閱讀
- GDDR和DDR代表什么?GDDR和DDR內存有什么區別? 1831次閱讀
- $monitor和$strobe有何差異? 511次閱讀
- 如何通過GTM Digital monitor讀RX Equalizer 520次閱讀
- 如何在不提高心率的情況下將心電圖添加到您的可穿戴設備中 718次閱讀
- FP-AI-MONITOR1簡介 1310次閱讀
- 在貼片加工廠中有哪些安全防護需要了解 1306次閱讀
- 復合放大器實現高精度的高輸出驅動能力 獲得最佳的性能 1600次閱讀
- 東大金智科技Formerica 10G XFP光模塊簡介英文版 1786次閱讀
- 用降壓型穩壓器或線性穩壓器電源時值來會為負載供電 984次閱讀
- 串口通信技術簡單總結和歸納 9357次閱讀
- 全面解讀Apollo 3.0 從研發到量產的技術原理 5478次閱讀
- 三星推出AR Emoji的另一個原因是——通過實時視頻解決帶寬問題 5010次閱讀
- gps追蹤器組成與硬件結構 9784次閱讀
下載排行
本周
- 1電子電路原理第七版PDF電子教材免費下載
- 0.00 MB | 1490次下載 | 免費
- 2單片機典型實例介紹
- 18.19 MB | 92次下載 | 1 積分
- 3S7-200PLC編程實例詳細資料
- 1.17 MB | 27次下載 | 1 積分
- 4筆記本電腦主板的元件識別和講解說明
- 4.28 MB | 18次下載 | 4 積分
- 5開關電源原理及各功能電路詳解
- 0.38 MB | 10次下載 | 免費
- 6基于AT89C2051/4051單片機編程器的實驗
- 0.11 MB | 4次下載 | 免費
- 7藍牙設備在嵌入式領域的廣泛應用
- 0.63 MB | 3次下載 | 免費
- 89天練會電子電路識圖
- 5.91 MB | 3次下載 | 免費
本月
- 1OrCAD10.5下載OrCAD10.5中文版軟件
- 0.00 MB | 234313次下載 | 免費
- 2PADS 9.0 2009最新版 -下載
- 0.00 MB | 66304次下載 | 免費
- 3protel99下載protel99軟件下載(中文版)
- 0.00 MB | 51209次下載 | 免費
- 4LabView 8.0 專業版下載 (3CD完整版)
- 0.00 MB | 51043次下載 | 免費
- 5555集成電路應用800例(新編版)
- 0.00 MB | 33562次下載 | 免費
- 6接口電路圖大全
- 未知 | 30320次下載 | 免費
- 7Multisim 10下載Multisim 10 中文版
- 0.00 MB | 28588次下載 | 免費
- 8開關電源設計實例指南
- 未知 | 21539次下載 | 免費
總榜
- 1matlab軟件下載入口
- 未知 | 935053次下載 | 免費
- 2protel99se軟件下載(可英文版轉中文版)
- 78.1 MB | 537791次下載 | 免費
- 3MATLAB 7.1 下載 (含軟件介紹)
- 未知 | 420026次下載 | 免費
- 4OrCAD10.5下載OrCAD10.5中文版軟件
- 0.00 MB | 234313次下載 | 免費
- 5Altium DXP2002下載入口
- 未知 | 233045次下載 | 免費
- 6電路仿真軟件multisim 10.0免費下載
- 340992 | 191183次下載 | 免費
- 7十天學會AVR單片機與C語言視頻教程 下載
- 158M | 183277次下載 | 免費
- 8proe5.0野火版下載(中文版免費下載)
- 未知 | 138039次下載 | 免費
評論
查看更多